solomon islands YN5-47 High-Temperature Boiler Induced Draft Fan

Category:

solomon islandsProducts

Product Description

Product Overview

- Drawing on advanced foreign prototypes, we are developing and designing new boiler fans tailored specifically for the boiler industry.
- High-temperature resistant, highly efficient, featuring high airflow, low vibration, and minimal noise—designed with a laser-cut fan housing for a sleek, aesthetically pleasing appearance.
- The motor is made from Y2 aluminum alloy die-cast material, significantly reducing its weight for lightweight design, easy installation, and a sleek, modern appearance.
- The main components of the electric motor are high-temperature-resistant materials (such as high-temperature bearings, high-temperature grease, and high-temperature insulation materials).
- The motor is cooled by connecting the insulated mounting bracket (equipped with internal cooling fins) to the air housing, ensuring optimal performance even in high-temperature conditions.
- Widely used in industries such as heating furnaces, hot-air stoves, CNC boilers, steam boilers, drying applications, chemical processing, food production, and grain machinery.
- Normal operating temperature of the fan: 180°C–200°C

 

304 Stainless Steel Available for Customization

 

Technical specifications

Model Power supply
Kw
Voltage
V
Frequency
Hz
Rotational speed
revolutions per minute
Traffic
m 3/h
Full pressure
Pa
YN5-47 60W 220/380 50 2800 240 310
YN5-47 90W 220/380 50 2800 350 360
YN5-47 120W 220/380 50 2800 480 450
YN5-47 180W 220/380 50 2800 650 510
YN5-47 250W 220/380 50 2800 860 580
YN5-47 370W 220/380 50 2800 1100 650
YN5-47 550W 220/380 50 2800 1450 680
YN5-47 750W 220/380 50 2800 1810 790
YN5-47 1.1KW 220/380 50 2800 2250 940
YN5-47 1.5KW 220/380 50 2800 2800 1140
YN5-47 2.2KW 220/380 50 2800 3100 1280
YN5-47 3KW 220/380 50 2800 3800 1580
YN5-47 4KW 220/380 50 2800 5000 2200
YN5-47 5.5KW 220/380 50 2800 6500 2600

 

Installation dimensions

 

Model Power Air outlet flange dimensions Inlet air duct flange dimensions Interface (optional)
A1 A2 A3 Φa * b B1 B2 B3 Φc * d ΦA Φ1 Φ2 Φ3 ΦB * n Exit Φ C Φ D Import
YN5-47 60 watts 61 95 118 1 × 95 60 95 118 1 × 95 8 100 135 156 Φ10 x 6 100 100
YN5-47 90 watts 59 85 122 1 * 85 85 115 141 1 × 115 10 100 135 156 Φ10 x 6 100 100
YN5-47 120w 60 92 138 1 * 92 110 150 176 1 × 150 10 108 146 166 Φ10 x 6 110 110
YN5-47 180w 60 92 138 1 * 92 110 150 176 1 × 150 10 108 146 166 Φ10 x 6 110 110
YN5-47 250w 62 93 139 1 * 93 121 160 186 1 × 160 11 128 180 207 Φ11 x 6 130 130
YN5-47 370w 78 109 155 1 × 109 121 160 186 1 × 160 11 128 180 207 Φ11 x 6 130 130
YN5-47 550w 85 116 162 1 × 116 136 176 202 1 × 176 11 150 200 224 Φ11 x 6 150 150
YN5-47 750w 102 133 179 1 × 133 136 176 202 2 × 88 11 150 200 224 Φ11 x 6 150 150
YN5-47 1.1kw 120 151 197 1 * 151 156 196 222 2 × 98 11 160 200 228 Φ11 x 6 165 165
YN5-47 1.5kw 131 162 208 1 × 162 176 216 242 2 × 108 11 160 200 228 Φ11 x 6 165 165
YN5-47 2.2kw 130 161 206 1 × 161 206 246 272 2 * 123 11 186 230 254 Φ11 x 6 190 190
YN5-47 3kw 155 188 217 2 × 94 180 213 243 2 × 106.5 11 213 254 284 Φ11 x 6 190 190
YN5-47 4kw 175 225 255 2 × 94 230 270 305 2 × 106.5 11 260 310 365 Φ11 x 6 190 190
YN5-47 5.5kw 190 235 265 2 × 94 280 326 355 2 × 106.5 11 260 330 365 Φ11 x 6 190 190

 

Model Power External dimensions Scaffolding dimensions (optional)
C1 C2 L1 L2 L3 L M N E F JM JN JH JL JC JF Japanese Encephalitis
YN5-47 60 watts 70 90 192 65 41 298 221 193 72 95 130 140 170 240 160 208 153
YN5-47 90 watts 70 90 192 62 41 295 259 223 85 108 130 140 170 240 160 208 153
YN5-47 120W 70 90 192 64 41 297 325 281 107 131 130 140 170 240 160 208 153
YN5-47 180W 70 90 192 64 41 297 325 281 107 131 130 140 170 240 160 208 153
YN5-47 250W 80 100 220 67 47 334 370 320 127 148 130 140 170 240 160 208 153
YN5-47 370W 80 100 220 83 47 350 370 320 127 148 130 140 170 240 160 208 153
YN5-47 550W 90 112 275 90 43 408 420 364 148 167 150 180 210 240 154 230 175
YN5-47 750W 90 112 275 108 43 426 420 364 148 167 150 180 210 240 154 230 175
YN5-47 1.1KW 100 125 300 125 44 467 470 408 166 185 150 184 213 240 166 228 204
YN5-47 1.5KW 100 140 325 135 42 502 506 438 176 202 190 215 241 280 193 248 195
YN5-47 2.2KW 125 140 345 135 45 525 549 478 186 222 190 215 241 280 193 253 195
YN5-47 3KW 140 160 385 157 50 592 610 495 234 238 245 220 260 400 280 310 266
YN5-47 4KW 140 190 385 157 50 670 640 600 234 238 245 220 260 400 280 310 266
YN5-47 5.5KW 140 216 385 157 50 710 670 575 234 238 245 220 260 400 280 310 266